Specifications are subject to change due to continuing engineering improvements and legislative changes. You are urged to contact us for current specifications prior to using this information in your projects.

The use of gas backup or full gas installations can have many benefits, such as staffing (reduced attendance during off-peak periods), logistics (keeping up a continuous supply of firewood fuel, or a breakdown in deliveries), shorter heating times from cold, or simply the advantages of a Beech oven where wood supply is scarce or the use of wood is prohibited by regulations.

Approvals / Compliance

  • CE rating Europe. The gas equipment used in Beech stone hearth ovens adheres to all CE directive requirements.
  • UK Smoke Free Zone Exemption. The full range of Beech Ovens can be used anywhere in the UK.
  • UL/EPH Rating USA. Please contact us for the separate sheets for UL listed products.

bbs015 (Feb 2003)

OVEN TYPEGAS BACKUPGAS BACKUPGAS BACKUPGAS ONLY *NO GAS
GAS TYPENATURALLPGTOWN GASALL GASESWOOD ONLY
Thermal Input80 MJ/Hr80 MJ/Hr80 MJ/Hr160 MJ/HrN/A
 76,000BTU76,000BTU76,000BTU152,000BTUN/A
Gas Supply Line19mm Cu19mm Cu19mm Cu2 x 19mm CuN/A
3/4"3/4"3/4"2 x 3/4"N/A
Power supply
- Outside USA
240 v 10A240 v 10A240v 10A240V 10AN/A
Power supply
- Mainland USA
110V 10A110V 10A110V 10A110V 10AN/A
Burner Jet Size4.1mm Diam2.30mm Diam5.6mm DiamSameN/A
Drill #20Drill #43Drill #2SameN/A
Gas pressure at burner injector1KPA2.75KPA0.6KPASameN/A
4"WC11" WC2.4" WCSameN/A
Gas supply pressure to inlet at isolating valve kPA7.0kPA MAX7.0kPA MAX7.0kPA MAXSameN/A
2kPA MIN3.0kPA MIN0.7kPA MINSameN/A
Gas Supply Pressure to Inlet at Isolating Valve PSI1 PSI MAX1 PSI MAX1 PSI MAXSameN/A
0.3 PSI , MIN0.45 PSI MIN0.1 PSI MINSameN/A
Gas Consumption per Hour (Approx)2.0 M3/Hr0.6 M3/Hr3.9 M3/HrDoubleN/A
72 Ft3 / Hr22 Ft3/ Hr130Ft3/HrDoubleN/A
Timber Consumption Hard Wood0.1 M3 Per Day0.1 M3 Per Day0.1 M3 Per DayN/A0.2 M3 per 12 hour day
3 CU Ft3 CU Ft3 CU FtSame6 CU Ft per 12 hour day
Duct size- Natural draft (or equivalent round)400mm SQ400mm SQ400mm SQSame400mm SQ
16" SQ16" SQ16" SQSame16" SQ
Duct size- Fan assisted (or equivalent round)300mm SQ300mm SQ300mm SQSame 300mm SQ
12" SQ12" SQ12" SQSame12" SQ
AIRFLOW REQUIRED
(ALL FUELS)
Single mouth oven; Min 700 Litres/Sec (1500Cfm); no maximum as suction is controlled by flue damper. Oven with grill; Min 1000 Litres/Sec (2000Cfm); no maximum as suction is controlled by flue damper.
Secondary Air for Gas Burner6.0 litres per second
(approx)
6.0 litres per second
(approx)
6.0 litres per second
(approx)
12.0 litres per second
(approx)
N/A
12 cfm approx12 cfm approx12 cfm approx24 cfm approx 
Air Conditioning Heat LoadLess than 2 Kw Heat Load (7000 Btu)

Note:
• Metric / Imperial conversions are close approximations and not necessarily exact.
• The term "same" or "double" in the "Gas only" ovens column means the same, or double, the specification for the type of gas in use, e.g. natural gas, LPG or Town gas.